What Does Emergency Heat Mean on a Thermostat?

Hand holding a battery beside a smart thermostat: what emergency heat means on a Phoenix heat pump

By the Diamond AC and Heating team · Serving the Phoenix Valley since 2008

Emergency heat (often shown as “EM Heat,” “EMER” or “E-Heat”) is a thermostat setting on heat pump systems that shuts off the outdoor heat pump and heats your home only with the backup heat source, which is usually electric heat strips inside the indoor air handler. It’s a manual override for when the heat pump itself has failed or is damaged. It is not a “turbo” mode for faster heat, and it isn’t the same as auxiliary (AUX) heat, which the system turns on automatically. In the Phoenix Valley, where winter nights rarely stay below freezing for long, most homeowners should almost never need to use it.

Key takeaways

  • Emergency heat = heat pump OFF, backup heat ON. You switch it on yourself, and it stays on until you switch it off.
  • AUX heat is automatic and temporary: the system adds backup heat while the heat pump keeps running. Seeing “AUX” on the display is usually normal.
  • Electric heat strips use far more electricity than a working heat pump, so leaving EM Heat on by accident can push up your SRP or APS bill quickly.
  • Use EM Heat only when the outdoor unit is clearly broken, iced over beyond a normal defrost cycle, or physically damaged, and then call for heat pump repair.
  • If the thermostat shows EM Heat when you didn’t select it, or the house stays cold even in EM Heat, that’s a service call, not a setting problem.

What Does Emergency Heat Mean on a Thermostat?

If your home has a heat pump (one outdoor unit that cools in summer and heats in winter), your thermostat probably has a mode labeled “Em Heat,” “Emergency Heat,” “EMER” or “E-Heat” alongside Heat, Cool and Off. That label tells you the system has two ways to make heat:

  1. Primary heat: the heat pump. The outdoor unit runs in reverse. Instead of pulling heat out of your house and dumping it outside like it does all summer, it pulls heat out of the outdoor air and moves it inside. Because it’s moving heat rather than creating it, this is the efficient way to heat a home.
  2. Secondary (backup) heat. In most Phoenix-area heat pump homes, this is a set of electric resistance heat strips (also called a heat kit) built into the indoor air handler. In some homes, especially “dual fuel” setups, the backup is a gas furnace.

When you choose Emergency Heat, the thermostat sends a signal that locks out the outdoor compressor completely and runs only the backup source. Your blower still moves air through the ducts, and the heat strips (or furnace) do all of the work.

If your thermostat doesn’t have an Em Heat option at all, you most likely have a straight air conditioner with a gas furnace, and the setting doesn’t apply to you. Not sure which you have? Our guide to the parts of a heat pump system walks through how to tell.

How Emergency Heat Works, Step by Step

Here’s what actually happens inside your system when you flip the thermostat to EM Heat:

  1. The thermostat de-energizes the compressor circuit. The outdoor unit stops running, even if it was working fine a moment ago.
  2. The backup heat circuit is energized. On most thermostats this is a separate terminal (often labeled E or EM) that tells the air handler to turn on the heat strips, or tells a dual-fuel system to fire the furnace.
  3. The indoor blower moves heated air. Air passes over the glowing heat strips, picks up heat and travels through your ducts to every room.
  4. A light or icon stays on. Most thermostats show a red light, an “EM” icon or a message for as long as the mode is active, so you know you’re running on backup only.
  5. Nothing changes until you change it. EM Heat doesn’t time out. It keeps running on backup heat until you switch the thermostat back to normal Heat.

Emergency Heat vs. AUX Heat: What’s the Difference?

This is the most common point of confusion, and it’s where most of the top-ranking articles on this topic stop short. AUX (auxiliary) heat and EM (emergency) heat often use the same heat strips, but they behave very differently.

QuestionAUX HeatEmergency Heat
Who turns it on?The thermostat, automaticallyYou, manually
Does the heat pump keep running?Yes, backup heat is added on top of itNo, the outdoor unit is locked out
How long does it run?Short bursts, then shuts off by itselfUntil you switch it off
Typical triggersDefrost cycle, a big jump in the set temperature, very cold morningsOutdoor unit broken, damaged or badly iced
Is it normal to see it?Yes, occasionallyOnly if you chose it on purpose
Energy useHigher than heat pump alone, but briefHighest; runs entirely on backup
What to doUsually nothing. Call if it shows constantlyUse temporarily and schedule repair

Smart thermostats such as Nest and Ecobee handle AUX heat on their own and let you set limits on when it can run. If you’re shopping for a new thermostat, our comparison of programmable vs. smart thermostats covers which features matter for heat pump homes.

When Should You Use Emergency Heat?

Use EM Heat only when the heat pump itself can’t do its job. Good reasons include:

  • The outdoor unit has stopped working (fan not spinning, compressor not starting, breaker for the outdoor unit keeps tripping) and the house is getting uncomfortably cold.
  • The outdoor coil is encased in ice and stays that way well beyond a normal defrost cycle. A light frost that clears on its own is normal. A solid block of ice is not. See how to deal with a frozen heat pump.
  • The outdoor unit is physically damaged, for example by a fallen branch, a monsoon-season storm, debris or a vehicle.
  • A technician tells you to while you wait for a part or a repair visit.

When you should NOT use emergency heat

  • To warm the house faster. EM Heat doesn’t heat quicker in any way that’s worth the extra electricity. Normal Heat mode will already bring in AUX heat if it needs a boost.
  • Just because it’s “cold” outside. Modern heat pumps keep working well below the lowest temperatures most of the Valley sees.
  • When the outdoor unit is steaming. White vapor rising from the outdoor unit on a chilly morning is usually the defrost cycle melting frost. That’s normal, and it ends on its own.
  • As a long-term workaround. If you’ve been on EM Heat for more than a day or two, the underlying problem still needs fixing.

Why Emergency Heat Can Spike Your SRP or APS Bill

A heat pump moves existing heat, so it can deliver several units of heat for every unit of electricity it uses. Electric heat strips convert electricity straight into heat, one-for-one. That means running on EM Heat typically uses several times more electricity than a properly working heat pump to keep the house at the same temperature.

In Phoenix that gap matters even more if you’re on a time-of-use or demand plan with SRP or APS. Heat strips tend to run hardest on cold early mornings, which can overlap with winter on-peak windows depending on your plan. A few days of accidental EM Heat can show up clearly on your next statement. We give in-person quotes after seeing your system.

If your heating bill jumped and you aren’t sure why, check the thermostat for an EM or AUX indicator first. Then make sure the air filter is clean, since a clogged filter makes the heat pump struggle and can make backup heat run more often.

Signs Emergency Heat Is On When It Shouldn’t Be

  • A red light, “EM,” “EMER” or “Emergency” message on the thermostat that you didn’t set.
  • The outdoor unit is silent while the indoor blower runs and the house is warming.
  • Your electric bill is noticeably higher than the same month last year with similar weather.
  • A faint “dusty” or hot-metal smell from the vents. Heat strips that haven’t run in months can burn off dust when they first come on. A brief smell is common; a strong or lasting burning smell is not. Read why your heater smells like burning for what’s normal.

On some systems, the thermostat or control board will switch to backup-only heat on its own when it senses a heat pump fault. If you see EM or a fault code you didn’t trigger, treat it as a sign the heat pump needs attention.

How to Turn Emergency Heat On and Off

Every brand is a little different, but the process usually looks like this:

  • Basic digital thermostats: Press the System or Mode button until “Em Heat” or “Emer” appears, then set your temperature. To turn it off, cycle the mode back to “Heat.”
  • Honeywell: Most models list “Em Heat” in the System menu. When it’s active, many Honeywell units show an “Em Heat” message or a red indicator.
  • Nest: Emergency heat is found in the thermostat’s heat pump settings or quick menu (only on heat pump systems with backup heat wired). It has to be turned on manually and switched off when you’re done.
  • Ecobee: Look under the system mode options for “Aux” or emergency heat, depending on the model. Ecobee also lets you set when AUX heat may run automatically.
  • Older slider or switch thermostats: There may be a separate “Em Ht” position on the mode switch.

If the buttons aren’t responding, or the display is blank, start with batteries and the breaker. Our thermostat troubleshooting guide covers the common fixes.

Emergency Heat Not Working? What to Check

If you switch to EM Heat and the house still isn’t warming, the problem is in the backup system or the airflow, not the heat pump. Before calling, check these safe items:

  1. Thermostat setting: Confirm the mode actually changed and the set temperature is above the current room temperature.
  2. Breakers: Heat strips are often on their own large double breaker in the main panel, sometimes labeled “Air Handler,” “Heat Strip” or “Furnace.” A tripped breaker here is common. Reset it once. If it trips again, leave it off and call.
  3. Air filter: A badly clogged filter can trip the heat strips’ high-limit safety switch, which shuts them off to prevent overheating.
  4. Supply vents and returns: Make sure furniture and rugs aren’t blocking them.
  5. Blower: Put your hand near a supply vent. No airflow at all points to a blower, control board or power issue.

Don’t open the air handler’s electrical panel. Heat strip circuits carry high voltage. If the basics don’t fix it, it’s time for professional heating repair. For more on warm-air problems, see our guide on an HVAC system not blowing hot air and our quick fixes for when AC heating isn’t working.

What Usually Causes a Heat Pump to Need Emergency Heat

When a Phoenix homeowner ends up relying on EM Heat, the root cause is usually one of these:

ProblemWhat you might noticeWhy it matters
Failed capacitor or contactorOutdoor unit hums or clicks but won’t startDesert summer heat is hard on electrical parts, and failures often show up the first time the system switches to heating
Reversing valve problemUnit runs but blows cool air in Heat modeThe valve that switches between heating and cooling is stuck
Defrost control issueOutdoor coil stays iced overThe system can’t clear frost, so it can’t pull heat from outdoors
Low refrigerant / leakWeak heat, ice on lines, long run timesThe heat pump can’t move enough heat; leaks need to be found and repaired
Outdoor fan motor failureFan blade not spinningNo airflow across the coil means no heat transfer
Thermostat or wiring faultErratic modes, EM light you didn’t setThe system may be locking out the heat pump unnecessarily

Many of these give warning signs before they fail completely. Our article on warning signs your heat pump needs emergency repair and our list of common heat pump issues go deeper on each one.

Emergency Heat in the Phoenix Valley: What’s Different Here

Most national articles about emergency heat are written for places with long, freezing winters. The Valley is different, and that changes how you should think about the setting.

Our heat pumps work hardest in summer, not winter

A Phoenix heat pump spends months running in cooling mode through triple-digit heat, then switches to heating for a relatively short, mild winter. That means the parts that fail in winter, like capacitors and contactors, have usually been weakened by summer, not by cold. The first chilly week of the year, typically in November or December, is when we see the most “my heat pump won’t heat” calls. That’s why a fall heating tune-up is worth doing before you need the heat.

Cold mornings, not cold days

Valley winter days are usually comfortable, but early mornings in outlying areas can dip near or below freezing. Homes in Surprise, Sun City and the far West Valley, plus higher-elevation spots in north Phoenix and Anthem, see more frost on outdoor units than central Phoenix does. A short defrost cycle (with some steam) on those mornings is normal. A unit that stays white with ice into the afternoon isn’t.

Monsoon dust and debris

Monsoon storms and haboobs pack outdoor coils with dust and can throw debris into the unit. A dirty coil makes the heat pump less efficient in winter too, so it leans on AUX heat more often. Learn more about how Arizona dust storms affect your system.

If you’re weighing whether a heat pump is the right fit for your home in the first place, read is a heat pump right for Phoenix homes? and our list of heat pump mistakes to avoid.

How to Avoid Needing Emergency Heat

  • Schedule heating maintenance every fall. A technician checks the capacitor, contactor, refrigerant charge, reversing valve, defrost controls and backup heat strips. See how often a heat pump should be serviced.
  • Change your filter on schedule. Dust is constant in the desert, and a clogged filter strains every part of the system.
  • Keep the outdoor unit clear. Leave a couple of feet of open space around it, and rinse dust off after monsoon storms.
  • Don’t make big thermostat jumps. Raising the set temperature a lot at once is one of the most common reasons AUX heat kicks in. Small, steady changes let the heat pump do the work.
  • Consider a maintenance plan. Our HVAC maintenance plan keeps spring and fall visits on the calendar so they don’t get missed.

Frequently Asked Questions

What does emergency heat do?

It turns off the outdoor heat pump and heats your home using only the backup heat source, which is usually electric heat strips in the indoor air handler or, on dual-fuel systems, a gas furnace. It keeps you warm when the heat pump can’t run.

What does emergency heat run off of?

In most Phoenix-area heat pump homes, emergency heat runs on electricity through resistance heat strips (a heat kit) in the air handler. In dual-fuel homes it runs the gas furnace instead. Either way, the outdoor compressor is not used.

Is it bad to run emergency heat all the time?

It won’t usually harm the equipment, but it is much less efficient than a working heat pump and can raise your electric bill significantly. It’s also a sign that something is wrong with the heat pump that should be repaired rather than worked around.

What is the difference between AUX heat and emergency heat?

AUX heat turns on automatically for short periods to help a running heat pump, such as during defrost. Emergency heat is turned on manually, shuts the heat pump off completely, and stays on until you turn it off.

At what temperature should I switch to emergency heat?

There isn’t a temperature that requires it. Switch to emergency heat because the heat pump has a problem, not because it’s cold outside. In normal Heat mode, the system will bring in AUX heat automatically when it needs help.

Why is my heat pump emergency heat not working?

Common causes are a tripped heat strip breaker, a tripped high-limit switch (often from a clogged filter), failed heat strips or sequencers, a blower problem or a thermostat wiring issue. Check the thermostat, breaker and filter, then call a technician if it still won’t heat.

Why is my heat pump emergency heat blowing cold air?

If EM Heat is on and the vents are blowing cool air, the backup heat isn’t energizing. The blower is running but the heat strips (or furnace) aren’t. That usually points to a breaker, limit switch, failed strip, sequencer or control issue that needs a technician.

What does emergency heat mean on a Honeywell thermostat?

It means the same thing as on any heat pump thermostat: the heat pump is off and the system is running on backup heat only. Honeywell thermostats usually show “Em Heat” on the display while the mode is active.

Need Heat Pump Help in the Phoenix Valley?

If you’ve had to switch to emergency heat, or your thermostat shows EM Heat and you don’t know why, the Diamond AC and Heating team can find the cause and get your heat pump working properly again. We’ve served Phoenix Valley homeowners since 2008 and offer 24/7 service, from north Phoenix to Glendale, Peoria and the rest of our service areas.

Call us any time, day or night, or request a free estimate online. Prefer to pick a time? Schedule HVAC service or explore our full range of heating services.

Scroll to Top